Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.744
Filtrar
1.
World J Gastroenterol ; 30(10): 1450-1460, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38596502

RESUMEN

BACKGROUND: Direct-acting antiviral agents (DAAs) are highly effective treatment for chronic hepatitis C (CHC) with a significant rate of sustained virologic response (SVR). The achievement of SVR is crucial to prevent additional liver damage and slow down fibrosis progression. The assessment of fibrosis degree can be performed with transient elastography, magnetic resonance elastography or shear-wave elastography (SWE). Liver elastography could function as a predictor for hepatocellular carcinoma (HCC) in CHC patients treated with DAAs. AIM: To explore the predictive value of SWE for HCC development after complete clearance of hepatitis C virus (HCV). METHODS: A comprehensive literature search of clinical studies was performed to identify the ability of SWE to predict HCC occurrence after HCV clearance. In accordance with the study protocol, a qualitative and quantitative analysis of the evidence was planned. RESULTS: At baseline and after 12 wk of follow-up, a trend was shown towards greater liver stiffness (LS) in those who go on to develop HCC compared to those who do not [baseline LS standardized mean difference (SMD): 1.15, 95% confidence interval (95%CI): 020-2.50; LS SMD after 12 wk: 0.83, 95%CI: 0.33-1.98]. The absence of a statistically significant difference between the mean LS in those who developed HCC or not may be related to the inability to correct for confounding factors and the absence of raw source data. There was a statistically significant LS SMD at 24 wk of follow-up between patients who developed HCC vs not (0.64; 95%CI: 0.04-1.24). CONCLUSION: SWE could be a promising tool for prediction of HCC occurrence in patients treated with DAAs. Further studies with larger cohorts and standardized timing of elastographic evaluation are needed to confirm these data.


Asunto(s)
Carcinoma Hepatocelular , Diagnóstico por Imagen de Elasticidad , Hepatitis C Crónica , Hepatitis C , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/etiología , Carcinoma Hepatocelular/tratamiento farmacológico , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/etiología , Neoplasias Hepáticas/tratamiento farmacológico , Hepacivirus , Diagnóstico por Imagen de Elasticidad/métodos , Antivirales/uso terapéutico , Hepatitis C Crónica/complicaciones , Hepatitis C Crónica/diagnóstico por imagen , Hepatitis C Crónica/tratamiento farmacológico , Respuesta Virológica Sostenida , Fibrosis , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/tratamiento farmacológico , Hepatitis C/tratamiento farmacológico
2.
Ultrasonics ; 140: 107312, 2024 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-38599075

RESUMEN

BACKGROUND: Shear wave elastography (SWE) is mainly used for stiffness estimation of large, homogeneous tissues, such as the liver and breasts. However, little is known about its accuracy and applicability in thin (∼0.5-2 mm) vessel walls. To identify possible performance differences among vendors, we quantified differences in measured wave velocities obtained by commercial SWE implementations of various vendors over different imaging depths in a vessel-mimicking phantom. For reference, we measured SWE values in the cylindrical inclusions and homogeneous background of a commercial SWE phantom. Additionally, we compared the accuracy between a research implementation and the commercially available clinical SWE on an Aixplorer ultrasound system in phantoms and in vivo in patients. METHODS: SWE measurements were performed over varying depths (0-35 mm) using three ultrasound machines with four ultrasound probes in the homogeneous 20 kPa background and cylindrical targets of 10, 40, and 60 kPa of a multi-purpose phantom (CIRS-040GSE) and in the anterior and posterior wall of a homogeneous polyvinyl alcohol vessel-mimicking phantom. These phantom data, along with in vivo SWE data of carotid arteries in 23 patients with a (prior) head and neck neoplasm, were also acquired in the research and clinical mode of the Aixplorer ultrasound machine. Machine-specific estimated phantom stiffness values (CIRS phantom) or wave velocities (vessel phantom) over all depths were visualized, and the relative error to the reference values and inter-frame variability (interquartile range/median) were calculated. Correlations between SWE values and target/vessel wall depth were explored in phantoms and in vivo using Spearman's correlations. Differences in wave velocities between the anterior and posterior arterial wall were assessed with Wilcoxon signed-rank tests. Intra-class correlation coefficients were calculated for a sample of ten patients as a measure of intra- and interobserver reproducibility of SWE analyses in research and clinical mode. RESULTS: There was a high variability in obtained SWE values among ultrasound machines, probes, and, in some cases, with depth. Compared to the homogeneous CIRS-background, this variation was more pronounced for the inclusions and the vessel-mimicking phantom. Furthermore, higher stiffnesses were generally underestimated. In the vessel-mimicking phantom, anterior wave velocities were (incorrectly) higher than posterior wave velocities (3.4-5.6 m/s versus 2.9-5.9 m/s, p ≤ 0.005 for 3/4 probes) and remarkably correlated with measurement depth for most machines (Spearman's ρ = -0.873-0.969, p < 0.001 for 3/4 probes). In the Aixplorer's research mode, this difference was smaller (3.3-3.9 m/s versus 3.2-3.6 m/s, p = 0.005) and values did not correlate with measurement depth (Spearman's ρ = 0.039-0.659, p ≥ 0.002). In vivo, wave velocities were higher in the posterior than the anterior vessel wall in research (left p = 0.001, right p < 0.001) but not in clinical mode (left: p = 0.114, right: p = 0.483). Yet, wave velocities correlated with vessel wall depth in clinical (Spearman's ρ = 0.574-0.698, p < 0.001) but not in research mode (Spearman's ρ = -0.080-0.466, p ≥ 0.003). CONCLUSIONS: We observed more variation in SWE values among ultrasound machines and probes in tissue with high stiffness and thin-walled geometry than in low stiffness, homogeneous tissue. Together with a depth-correlation in some machines, where carotid arteries have a fixed location, this calls for caution in interpreting SWE results in clinical practice for vascular applications.

3.
BMC Cancer ; 24(1): 409, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38566057

RESUMEN

BACKGROUND: Accurate evaluation of axillary lymph node metastasis (LNM) in breast cancer is very important. A large number of hyperplastic and dilated lymphangiogenesis cases can usually be found in the pericancerous tissue of breast cancer to promote the occurrence of tumor metastasis.Shear wave elastography (SWE) can be used as an important means for evaluating pericancerous stiffness. We determined the stiffness of the pericancerous by SWE to diagnose LNM and lymphangiogenesis in invasive breast cancer (IBC). METHODS: Patients with clinical T1-T2 stage IBC who received surgical treatment in our hospital from June 2020 to December 2020 were retrospectively enrolled. A total of 299 patients were eventually included in the preliminary study, which included an investigation of clinicopathological features, ultrasonic characteristics, and SWE parameters. Multivariable logistic regression analysis was used to establish diagnostic model and evaluated its diagnostic performance of LNM. The correlation among SWE values, collagen volume fraction (CVF), and microlymphatic density (MLD) in primary breast cancer lesions was analyzed in another 97 patients. RESULTS: The logistic regression model is Logit(P)=-1.878 + 0.992*LVI-2.010*posterior feature enhancement + 1.230*posterior feature shadowing + 0.102*posterior feature combined pattern + 0.009*Emax. The optimum cutoff value of the logistic regression model was 0.365, and the AUC (95% CI) was 0.697 (0.636-0.758); the sensitivity (70.7 vs. 54.3), positive predictive value (PPV) (54.0 vs. 50.8), negative predictive value (NPV) (76.9 vs. 69.7), and accuracy (65.2 vs. 61.9) were all higher than Emax. There was no correlation between the SWE parameters and MLD in primary breast cancer lesions. CONCLUSIONS: The logistic regression model can help us to determine LNM, thus providing more imaging basis for the selection of preoperative treatment. The SWE parameter of the primary breast cancer lesion cannot reflect the peritumoral lymphangiogenesis, and we still need to find a new ultrasonic imaging method.


Asunto(s)
Neoplasias de la Mama , Diagnóstico por Imagen de Elasticidad , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Linfangiogénesis , Metástasis Linfática/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Estudios Retrospectivos
4.
J Clin Med ; 13(7)2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38610821

RESUMEN

Objectives: The objective is to compare stiffness changes around the shoulder muscles between pitchers and position players after throwing overhead using shear wave elastography (SWE) in relation to throwing motion analysis and muscle strength. Methods: A total of 32 male college baseball players (12 pitchers and 20 position players) were observed throwing 20 times, and SWE was performed to evaluate 13 shoulder muscle items-tendons (supraspinatus, infraspinatus, subscapularis, and teres minor), muscles (supraspinatus, infraspinatus [transverse and oblique part], teres minor, lower trapezius, latissimus dorsi, and pectoralis minor), and capsules (posterior and posteroinferior). Motion analysis was used to assess elbow torque, forearm angle, forearm rotation speed, and maximum external rotation angle of the shoulder. Muscle strength was measured using a dynamometer for abduction, internal/external rotation of the shoulder at an abduction of 0°, internal/external rotation of the shoulder at an abduction of 90°, and internal/external rotation of shoulder at a flexion of 90°. Results: In the pitcher group, SWE values for the teres minor muscle and latissimus dorsi muscle increased significantly after throwing. In the position player group, SWE values for the teres minor muscle significantly increased, and SWE values of the pectoralis minor muscle decreased after throwing. In the pitcher group, positive correlations were found between the teres minor muscle and forearm rotation speed and between the latissimus dorsi muscle and forearm angle. No significant difference was found in muscle strength after throwing in any of the groups. Conclusions: Stiffness changes occurred after throwing and were related to the motion analysis, but the regions in which stiffness occurred varied between pitchers and position players.

5.
Curr Med Imaging ; 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38639285

RESUMEN

PURPOSE: This study is to investigate the effectiveness of Acoustic Radiation Force Impulse (ARFI) elastography in differentiating radiologically similar renal cell carcinoma (RCC) and oncocytoma in solid masses of the kidney. METHODS: The patients with solid renal mass histopathological diagnosed after excision or tru-cat biopsy who underwent a preoperative ARFI elastography of the lesion during a 4-year period were included in this study. Preoperative shear wave velocity (SWV) values were measured in all the lesions. SWV results of RCCs and oncocytomas were compared by an independent t-test, and cut-off, sensitivity and specificity values were calculated. RESULTS: Forty-two of the 60 patients included in the study were men (70%) and, 18 were women (30%), and the mean age was 59.7 ± 14 (27-94) years. Among 46 RCCs (76.6%), 23 and 14 oncocytomas, 5 (23.4%) were located in the right kidney (p:0.34722). Mean SWV values were found to be significantly higher in RCCs (2.87± 0.74 (0.96-4.14) m/s) than oncocytomas (1.83 ± 0.78 (0.80-3.76) m/s) (p <0.001). In the ROC analysis, a cutoff value of 2.29 m/s was found to havean 80.4% sensitivity and a 78.6% specificity for the discrimination of RCCs from oncocytomas. CONCLUSION: ARFI elastography measurements may be useful in distinguishing RCC and oncocytomas that may have similar solid radiological imaging features.

6.
Phys Med ; 121: 103356, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38603998

RESUMEN

PURPOSE: Shear-wave elastography (SWE) provides quantitative and absolute metrics for analyzing the elasticity of soft tissues. Despite the anterior scalene muscle (AS) is a key structure in patients with neck pain and nerve compressive syndromes, the majority of SWE studies only included asymptomatic subjects. This study aimed to analyze the Young's modulus and shear wave speed test-retest reliability in a sample of patients with neck pain symptoms to characterize the AS stiffness. METHODS: A diagnostic accuracy study acquiring a set of ultrasound images at C7 level in 42 patients with mechanical neck pain by one experienced examiner. After blinding the participants' identity, trial and side, the Young's modulus and shear wave velocity were measured by an independent experienced rater in randomized order. Intra-class correlation coefficients (ICC), standard error of measurement (SEM), minimal detectable changes (MDC) and coefficient of variation (CV%) were calculated. RESULTS: The sample reported moderate pain intensity (5.9/10 points) and disability (17.38/100 points). AS stiffness metrics assessed showed no significant differences between males and females, left and right side nor painful and non-painful side. (all, p > 0.05). Intra-examiner reliability was excellent for calculating the Young's modulus for shear wave speed (ICC > 0.90). CONCLUSION: The results support the use of this procedure for assessing the AS stiffness in populations with mechanical neck pain as excellent reliability estimates were obtained. However, future research should analyze case-control differences and the association between SWE metrics with clinical severity indicators.

7.
Biol Reprod ; 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38609185

RESUMEN

The ovary is one of the first organs to show overt signs of aging in the human body, and ovarian aging is associated with a loss of gamete quality and quantity. The age-dependent decline in ovarian function contributes to infertility and an altered endocrine milieu, which has ramifications for overall health. The aging ovarian microenvironment becomes fibro-inflammatory and stiff with age, and this has implications for ovarian physiology and pathology, including follicle growth, gamete quality, ovulation dynamics, and ovarian cancer. Thus, developing a non-invasive tool to measure and monitor the stiffness of the human ovary would represent a major advance for female reproductive health and longevity. Shear wave elastography is a quantitative ultrasound imaging method for evaluation of soft tissue stiffness. Shear wave elastography has been used clinically in assessment of liver fibrosis and characterization of tendinopathies and various neoplasms in thyroid, breast, prostate, and lymph nodes as a non-invasive diagnostic and prognostic tool. In this study, we review the underlying principles of shear wave elastography and its current clinical uses outside the reproductive tract as well as its successful application of shear wave elastography to reproductive tissues, including the uterus and cervix. We also describe an emerging use of this technology in evaluation of human ovarian stiffness via transvaginal ultrasound. Establishing ovarian stiffness as a clinical biomarker of ovarian aging may have implications for predicting the ovarian reserve and outcomes of Assisted Reproductive Technologies as well as for the assessment of the efficacy of emerging therapeutics to extend reproductive longevity. This parameter may also have broad relevance in other conditions where ovarian stiffness and fibrosis may be implicated, such as polycystic ovarian syndrome, late off target effects of chemotherapy and radiation, premature ovarian insufficiency, conditions of differences of sexual development, and ovarian cancer. Summary sentence:  Shear Wave Elastography is a non-invasive technique to study human tissue stiffness, and here we review its clinical applications and implications for reproductive health and disease.

8.
J Ultrasound ; 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38613661

RESUMEN

PURPOSE: Shear wave elastography (SWE) has seen many advancements in Achilles tendon evaluation in recent years, yet standardization of this technique is still problematic due to the lack of knowledge regarding the optimal way to perform the examination. The purpose of this study was to evaluate the effects of ankle position, probe frequency and physical effort on the shear modulus of the Achilles tendon, but also to determine the intra and inter-observer reliability of the technique. METHODS: 37 healthy volunteers were included; SWE protocol was performed by two examiners. We analyzed the shear modulus of the tendon with the ankle in neutral, maximum dorsiflexion and maximum plantar flexion using two different high frequency probes. Afterwards, the subjects performed a brief physical exercise and SWE measurements were repeated. RESULTS: The L18-5 probe showed the highest ICC values (ICC = 0.798, 95% CI 0.660-0.880, p < 0.001) when positioned at 2 cm from the calcaneal insertion with the ankle in a neutral state. Conversely, utilizing the same L18-5 probe at 1 cm from the insertion during maximum plantar flexion of the ankle resulted in the lowest ICC (ICC = 0.422, 95% CI 0.032-0.655, p = 0.019). Significant variations in elasticity values were noted among different ankle positions and probe types, while no significant changes in elasticity were observed post-physical exercise. CONCLUSION: Ankle position and probe frequency are factors that influence elasticity values of the Achilles tendon. An ankle position between 10 and 20 degrees of plantar flexion is the most suitable for SWE evaluation. However, more research focusing on Achilles tendon SWE is essential due to the challenges encountered in standardizing this region.

9.
Rom J Intern Med ; 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38656816

RESUMEN

BACKGROUND: Metabolic-associated fatty liver disease and liver fibrosis are intimately linked to insulin resistance, type 2 diabetes, obesity, and metabolic syndrome. Transient elastography (TE) and point shear wave elastography (pSWE) were used to measure liver stiffness in patients who met the ultrasound criteria for steatotic liver diseases (SLD). This study compared two methods for estimating liver stiffness in patients with SLD, which in turn correlated with liver fibrosis. METHOD: Ultrasound B-mode imaging was used to identify SLD. In total, 250 MAFLD patients were recruited. Patient characteristics, laboratory investigations, and liver stiffness measurements using TE and pSWE were assessed on the same day. RESULTS: In the study, 56.0% of the patients were male, with a mean age of 41.5 ± 10.7 years. The correlation between TE and pSWE was significant (Spearman's r = 0.867*, p < .001). The Bland-Altman Plot analysis confirmed this, with 97.5% of variations in LSM falling within 95% agreement ranges. Cohen's κ was used to assess the agreement between TE and pSWE fibrosis stages, showing almost perfect agreement (83.5% kappa agreement) and a strong association between pSWE and TE in the assessment fibrosis stages. CONCLUSION: In patients with MAFLD, TE, and SWE are reliable methods for measuring liver stiffness and can be used as non-invasive screening tools for the assessment of fibrosis in SLD.

10.
Laryngoscope Investig Otolaryngol ; 9(2): e1249, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38651078

RESUMEN

Objectives: To provide a comprehensive summary of the different modalities available to measure soft tissue fibrosis after radiotherapy in head and neck cancer patients. Data Sources: PubMed, Scopus, and Web of Sciences. Review Methods: A search was conducted using a list of medical subject headings and terms related to head and neck oncology, radiation fibrosis, and quantitative measurements, including bioimpedance, MRI, and ultrasound. Original research related to quantitative measurement of neck fibrosis post-radiotherapy was included without time constraints, while reviews, case reports, non-English texts, and inaccessible studies were excluded. Discrepancies during the review were resolved by discussing with the senior author until consensus was reached. Results: A total of 284 articles were identified and underwent title and abstract screening. Seventeen articles had met our criteria for full-text review based on relevance, of which nine had met our inclusion criteria. Young's modulus (YM) and viscoelasticity measures have demonstrated efficacy in quantifying neck fibrosis, with fibrotic tissues displaying significantly higher YM values and altered viscoelastic properties such as increased stiffness rate-sensitivity and prolonged stress-relaxation post-radiation. Intravoxel incoherent motion offers detailed insights into tissue changes by assessing the diffusion of water molecules and blood perfusion, thereby differentiating fibrosed from healthy tissues. Shear wave elastography has proven to be an effective technique for quantifying radiation-induced fibrosis in the head and neck region by measuring shear wave velocity. Conclusion: There are various modalities to measure radiation-induced fibrosis, each with its unique strengths and limitations. Providers should be aware of these implications and decide on methodologies based on their specific clinical workflow. Level of Evidence: Step 5.

11.
Ultrason Imaging ; : 1617346241247127, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38651542

RESUMEN

This study addresses a crucial necessity in the field of noninvasive liver fibrosis diagnosis by introducing the concept of continuous shear wave elastography (C-SWE), utilizing an external vibration source and color Doppler imaging. However, an application of C-SWE to assess liver elasticity, a deep region within the human body, arises an issue of signal instability in the obtained data. To tackle this challenge, this work proposes a method involving the acquisition of multiple frames of datasets, which are subsequently compressed. Furthermore, the proposed frame-to-frame equalization method compensates discrepancies in the initial phase that might exist among multiple-frame datasets, thereby significantly enhancing signal stability. The experimental validation of this approach encompasses both phantom tests and in vivo experiments. In the phantom tests, the proposed technique is validated through a comparison with the established shear wave elastography (SWE) technique. The results demonstrate a remarkable agreement, with an error in shear wave velocity of less than 4.2%. Additionally, the efficacy of the proposed method is confirmed through in vivo tests. As a result, the stabilization of observed shear waves using the frame-to-frame equalization technique exhibits promising potential for accurately assessing human liver elasticity. These findings collectively underscore the viability of C-SWE as a potential diagnostic instrument for liver fibrosis.

12.
Clin Transl Radiat Oncol ; 46: 100773, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38590328

RESUMEN

Purpose: To assess radiation-induced fibrosis (RIF) using shear-wave elastography (SWE) in patients with breast cancer who received radiotherapy (RT) after breast conserving surgery. Methods: Forty-one patients were enrolled in a prospective study before RT. SWE and B-mode ultrasonography were performed to measure elasticity. For quantitative measurement, the maximum elasticity value was measured in the tumor bed and non-tumor bed of the treated breast, and contralateral breast before RT and at 3, and 12 months after RT. and RIF was recorded using the Common Terminology Criteria for Adverse Events (CTCAE) version 5.0. Results: The mean ± standard deviation elasticity values for the tumor bed, non-tumor bed, and contralateral breast were 71.2 ± 74.9 kPa, 19.4 ± 9.8 kPa and 20.3 ± 10.0 kPa before RT; 28.7 ± 26.3 kPa, 15.1 ± 7.0 kPa, and 14.7 ± 6.3 kPa at 12 months after RT, respectively. The elasticity values for all three measurement areas before and 12 months after RT were significantly different (p < 0.001 for tumor bed, p = 0.002 for non-tumor bed, p = 0.001 for contralateral breast). At 12 months follow-up, the distribution of grades of RIF evaluated by CTCAE grade was grade 0 in 43.9 %, grade 1 in 48.8 %, and grade 2 in 7.3 %. Conclusion: We demonstrated that SWE enables the evaluation of tissue stiffness to provide quantified information for the RIF of breast cancer. Further studies with long-term follow-up should provide more quantitative data.

13.
Front Oncol ; 14: 1366876, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38590661

RESUMEN

Aim: This study assessed the utility of multimodal ultrasound in enhancing the accuracy of breast cancer sentinel lymph node (SLN) assessment and compared it with single-modality ultrasound. Methods: Preoperative examinations, including two-dimensional ultrasound (2D US), intradermal contrast-enhanced ultrasound (CEUS), intravenous CEUS, shear-wave elastography (SWE), and surface localization, were conducted on 86 SLNs from breast cancer patients. The diagnostic performance of single and multimodal approaches for detecting metastatic SLNs was compared to postoperative pathological results. Results: Among the 86 SLNs, 29 were pathologically diagnosed as metastatic, and 57 as non-metastatic. Single-modality ultrasounds had AUC values of 0.826 (intradermal CEUS), 0.705 (intravenous CEUS), 0.678 (2D US), and 0.677 (SWE), respectively. Intradermal CEUS significantly outperformed the other methods (p<0.05), while the remaining three methods had no statistically significant differences (p>0.05). Multimodal ultrasound, combining intradermal CEUS, intravenous CEUS, 2D US, and SWE, achieved an AUC of 0.893, with 86.21% sensitivity and 84.21% specificity. The DeLong test confirmed that multimodal ultrasound was significantly better than the four single-modal ultrasound methods (p<0.05). Decision curve analysis and clinical impact curves demonstrated the superior performance of multimodal ultrasound in identifying high-risk SLN patients. Conclusion: Multimodal ultrasound improves breast cancer SLN identification and diagnostic accuracy.

14.
Skeletal Radiol ; 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38526811

RESUMEN

OBJECTIVES: To correlate the cross-sectional area (CSA) and elasticity of the median nerve (MN) measured at carpal tunnel inlet between healthy controls and various degrees of carpal tunnel syndrome (CTS) graded as per nerve conduction studies (NCS). MATERIALS AND METHODS: A total of 53 patients (with 81 wrists) presenting with clinical symptoms characteristic of CTS, having their diagnosis confirmed and severity graded by NCS, and 48 healthy controls (with 96 wrists) were included in the study. All the study participants underwent wrist ultrasound which included initial Grey-scale USG followed by strain and shear wave elastography. The CSA and elasticity (in terms of strain ratio and shear modulus) of MN were measured at the carpal tunnel inlet. Statistical analysis was performed using the Mann-Whitney U test to compare between the two groups and for subgroup analysis of cases. The diagnostic performance of each variable was evaluated using the receiver operating characteristic curves. RESULTS: The mean CSA was 9.20 ± 1.64, 11.48 ± 1.05, 14.83 ± 1.19 and 19.87 ± 2.68 mm2, the mean shear modulus was 17.93 ± 2.81, 23.59 ± 2.63, 32.99 ± 4.14 and 54.26 ± 9.24 kPa and the mean strain ratio was 5.26 ± 0.68, 5.56 ± 0.70, 7.03 ± 0.47 and 8.81 ± 0.94 in control, mild, moderate and severe grades of CTS, respectively (p < 0.001). CONCLUSION: The combined utility of Grey-scale USG and Elastography may serve as a painless and cost-effective alternative to NCS in grading the severity of CTS.

15.
Curr Med Imaging ; 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38500278

RESUMEN

BACKGROUND: Chronic Kidney Disease [CKD] affects individuals of different age groups worldwide. Moreover, CKD is associated with several risk factors, including obesity, lifestyle, and hypertension, which are common in the Middle East. Ultrasonography is the examination of choice for CKD. In recent years, Shear Wave Elastography [SWE] has developed through the continued development of ultrasound and received substantial attention ;therefore, it can be used to measure tissue stiffness. The study aimed to use point Shear Wave Elastography [p-SWE] to determine the correlation between diabetes and cortical renal thickness in detecting pathologies. METHODS: This study was performed at the King Abdul-Aziz University Hospital. We examined 61 patients who underwent SWE. The patients were classified into two groups based on the presence or absence of type 2 Diabetes Mellitus [DM]. RESULTS: The results showed that there was a significant correlation between cortical stiffness and DM duration [p<0.005]. In addition, there was a negative correlation between cortical stiffness and cortical thickness [p=0.147] in patients with DM. Moreover, the eGFR decreased with an increase in cortical stiffness [p=0.499]. The cortical thickness in patients with and without DM was 0.750 ± 0.2 kPa and 0.788 ± 0.4 kPa, respectively. The kidney stiffness in patients with DM and control patients was 8.5 ± 8.6 cm and 14.0 ± 25.16 cm, respectively. CONCLUSION: This study showed that kidney p-SWE measurements were reliable. Therefore, further studies assessing kidney stiffness in patients with and without people with diabetes are recommended.

16.
Ultrasound Med Biol ; 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38514363

RESUMEN

OBJECTIVE: Tissue susceptibility to histotripsy disintegration has been reported to depend on its elastic properties. This work was aimed at investigation of histotripsy efficiency for liquefaction of human hematomas, depending on their stiffness and degree of retraction over time (0-10 d). METHODS: As an in vitro hematoma model, anticoagulated human blood samples (200 mL) were recalcified at different temperatures. In one set of samples, the shear modulus was measured by shear wave elastography during blood clotting at 10℃, 22℃ and 37℃, and then daily during further aging. The ultrastructure of the samples was analyzed daily with scanning electron microscopy (SEM). Another set of blood samples (50-200 mL) were recalcified at 37℃ for density and retraction measurements over aging and exposed to histotripsy at varying time points. Boiling histotripsy (2.5 ms pulses) and hybrid histotripsy (0.2 ms pulses) exposures (2 MHz, 1% dc, P+/P-/As = 182/-27/207 MPa in situ) were used to produce either individual cigar-shaped or volumetric (0.8-3 mL) lesions in samples incubated for 3 h, 5 d and 10 d. The obtained lesions were sized, then the lysate aspirated under B-mode guidance was analyzed ultrastructurally and diluted in distilled water for sizing of residual fragments. RESULTS: It was found that clotting time decreased from 113 to 25 min with the increase in blood temperature from 10℃ to 37℃. The shear modulus increased to 0.53 ± 0.17 kPa during clotting and remained constant within 8 d of incubation at 2℃. Sample volumes decreased by 57% because of retraction within 10 d. SEM revealed significant echinocytosis but unchanged ultrastructure of the fibrin meshwork. Liquefaction rate and lesion dimensions produced with the same histotripsy protocols correlated with the increase in the degree of retraction and were lower in retracted samples versus freshly clotted samples. More than 80% of residual fibrin fragments after histotripsy treatment were shorter than 150 µm; the maximum length was 208 µm, allowing for unobstructed aspiration of the lysate with most clinically used needles. CONCLUSION: The results indicate that hematoma susceptibility to histotripsy liquefaction is not entirely determined by its stiffness, and correlates with the retraction degree.

17.
J Oral Rehabil ; 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38514822

RESUMEN

BACKGROUND: Microvascular complications of diabetes mellitus (DM) include oral manifestations and complications, including xerostomia, reduced salivary flow, susceptibility to infection, periodontal disease and salivary gland enlargement. OBJECTIVE: The present study aims to evaluate B-mode ultrasonography (USG) parameters such as size, volume and echogenicity of the submandibular and parotid salivary glands on both sides, shear-wave elastography (SWE) value and colour Doppler properties in patients with DM and healthy control groups. METHODS: In total, 160 right and left submandibular glands and 160 right and left parotid glands of 80 patients, 40 patients (20 type 1 DM, 20 type 2 DM) and 40 healthy control group, between the ages of 18-70 were examined by USG. Echogenicity, parenchyma internal structure, margin and dimensional measurements (antero-posterior length, supero-inferior length, medio-lateral length and volume) and colour Doppler with 'ML 6-15-D Matrix Array (4-15 MHz)' probe, shear-wave elastography '9L-D (2-8 MHz)' probe was investigated. RESULT: Statistically significant difference was observed in echogenicity in the right submandibular gland, echogenicity in the right parotid gland, margin characteristics, parenchymal homogeneity and colour Doppler characteristics between the type 1 DM, type 2 DM and control groups (p < .05). It was observed that the size, volume and SWE values of both submandibular and parotid glands were higher in the DM patient group than in the control group. Higher values were observed in type 2 DM compared to type 1 DM in the patient group. CONCLUSION: USG is an effective imaging technique in investigating the effects of diabetes on the submandibular and parotid salivary glands.

18.
J Ultrasound Med ; 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38516753

RESUMEN

OBJECTIVES: This study examines the associations between the median nerve (MN) shear wave elastography (SWE), the MN cross-sectional area (CSA), patient's symptoms, and the neurophysiological severity of carpal tunnel syndrome (CTS). The most appropriate site to perform SWE was also tested. METHODS: This prospective study comprised 86 wrists of 47 consecutive patients who volunteered for MN ultrasound after an electrodiagnostic study. The neurophysiological severity of CTS was assessed according to the results of a nerve conduction study (NCS). The MN CSA was measured at the carpal tunnel inlet (wCSA) and the forearm (fCSA). SWE was performed on the MN in a longitudinal orientation at the wrist crease (wSWE), at the forearm (fSWE), and within the carpal tunnel (tSWE). RESULTS: The wCSA and wSWE correlated positively with the neurophysiological severity of CTS (r = .619, P < .001; r = .582, P < .001, respectively). The optimal cut-off values to discriminate the groups with normal NCS and with findings indicating CTS were 10.5 mm2 for the wCSA and 4.12 m/s for the wSWE. With these cut-off values, wCSA had a sensitivity of 80% and specificity of 87% and wSWE a sensitivity of 88% and specificity of 76%. Neither tSWE nor fSWE correlated with the neurophysiological severity of CTS or differed between NCS negative and positive groups (P = .429, P = .736, respectively). CONCLUSION: Shear wave velocity in the MN at the carpal tunnel inlet increases in CTS and correlates to the neurophysiological CTS severity equivalently to CSA measured at the same site.

19.
Nagoya J Med Sci ; 86(1): 104-109, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38505715

RESUMEN

Prostaglandin E1 intracavernous injection test is an established method for diagnosing erectile dysfunction. However, the evaluation is non-objective and often influenced by the evaluator's subjectivity. Herein, we measured and objectively evaluated shear wave elastography results of the corpus cavernosum before and after injection in 16 patients who underwent prostaglandin E1 testing. The response score of prostaglandin E1 tests were "1" in 2 cases, "2" in 2 cases, and "3" in 12 cases. The average transmission velocity before the injection and at the time of maximum erection after the injection were 2.21 m/s and 1.57 m/s, respectively. Transmission velocity decreased during erection in 14 of 16 cases (87.5%). The overall rate of change in transmission velocity due to injection was -26.7% and was significantly different between the poor (responses 1 and 2: -16.1%) and good erection (response 3: -30.2%) groups. To the best of our knowledge, this is the first attempt to evaluate erectile phenomenon using percutaneous ultrasonic elastography in Japan. Rate of change in shear wave transmission velocity due to prostaglandin E1 injection in the corpus cavernosum penis was associated with the degree of erection. Therefore, the rate of change in shear wave transmission velocity in the corpus cavernosum penis could be used as an objective index of erectile phenomenon. Percutaneous ultrasonic elastography is a non-invasive and useful test method for diagnosing erectile dysfunction, determining the therapeutic effect, and predicting prognosis.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Disfunción Eréctil , Masculino , Humanos , Disfunción Eréctil/diagnóstico por imagen , Disfunción Eréctil/tratamiento farmacológico , Alprostadil/uso terapéutico , Diagnóstico por Imagen de Elasticidad/métodos , Erección Peniana/fisiología , Pene/diagnóstico por imagen
20.
Diagnostics (Basel) ; 14(6)2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38535025

RESUMEN

Liver stiffness measurement (LSM) by Fibroscan is the most used non-invasive method to assess liver fibrosis. Recently, point-shear wave elastography (pSWE) has been introduced as a simple alternative non-invasive test. Therefore, we aimed to compare the results of these two techniques. One hundred and eighty-four consecutive patients attending our outpatient ultrasound clinic were recruited. LSM was performed by both Fibroscan and pSWE. Statistical analysis was conducted by Spearman's test for correlation and linear regression. Bland-Altman graphs and ROC curves were drawn with area under the curve (AUC). Overall, the correlation of LS between Fibroscan and pSWE was substantial (r = 0.68, p < 0.001). Linear regression showed a coefficient b= 0.94 ± 0.02. The Bland-Altman plot found a bias of -0.10, with only 11 values exceeding the 95% confidence interval. When only considering patients with a LSM of > 10 kPa (n = 31), we found an excellent r = 0.79 (0.60-0.90, p < 0.001). A cutoff of 12.15 kPa for pSWE had sensitivity = 74.2% and specificity = 99.3% to detect relevant fibrosis, with an AUC = 0.98. The highest correlation was observed for hepatitis C (r = 0.91) and alcoholic liver disease (ALD)(r = 0.99). In conclusion, pSWE shows LSM estimation in agreement with Fibroscan in most cases, and the best concordance was observed for hepatitis C and ALD, and for higher ranges of LS.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...